Ali Erginay · enciclopedia

Publicaciones › Interfase vitreomacular, agujero macular y miopía alta

Measurement of full-thickness macular hole size using en face optical coherence tomography

Medición del tamaño de agujeros maculares de espesor total utilizando tomografía de coherencia óptica en face

Año2017
FuenteEye (London, England)
Tipoarticle · Journal Article, Observational Study
Autores (6)E Philippakis, M Legrand, M El Sanharawi, A Erginay, A Couturier, R Tadayoni
Posición de Erginay4 de 6
Citas18 (OpenAlex)
EnlacesDOI 10.1038/eye.2017.254 · PubMed 29219961 · OpenAlex · Texto completo en acceso abierto
LíneasInteligencia artificial y análisis automático de imágenes Enfermedades vasculares, genéticas e inflamatorias de la retina Interfase vitreomacular, agujero macular y miopía alta Imagen retiniana: OCT, OCT-angiografía y ultra-gran campo

En pocas palabras

Se estudió la medición del tamaño de agujeros maculares utilizando tomografía de coherencia óptica en face y se comparó con mediciones manuales en B-scans. Los resultados mostraron que la medición en face es factible y fiable, y no hay diferencia significativa con las mediciones manuales. Esto podría ofrecer una opción automática y fácil de usar para la práctica clínica.

Resumen divulgativo generado automáticamente a partir del resumen original; puede contener imprecisiones.

Resumen original

PurposeTo assess the feasibility and interest of measuring macular hole (MH) size using en face optical coherence tomography (OCT) compared with manual diameter measurements on B-scans.MethodsAmong our previously published series of 100 patients operated for primary MH, patients whose images were acquired with Cirrus 5000 HD-OCT (Carl Zeiss Meditec) with a quality signal strength >5/10 were included. Three segmentations (internal limiting membrane, horizontal, and retinal pigment epithelium (RPE)) were compared for obtaining the most appropriate en face image. MH surface areas were measured using ImageJ software. Mean diameters calculated from surface areas (diameter=2 × √(surface area/π)) were compared with those measured on B-scans.ResultsNineteen patients were included with a mean age of 72±8 years (56-86) and a female predominance (3/16). The mean absolute difference between horizontal and vertical diameters measured on B-scans was of 54±47 μm (0-180) without reaching significance (P=0.874). RPE segmentation provided the best en face image and was feasible without and with adjustment, respectively, in 79% and 100% (cases with vitreomacular traction) of cases. No significant difference in mean diameters was observed between those calculated from en face images (435±143 μm (195-693)) and those measured on horizontal B-scans (426±139 μm (214-705), P=0.482).ConclusionMeasuring MH size on en face OCT images is feasible, reliable, and eliminates the potential bias related to manual measurements on B-scans. Its integration into OCT devices would offer an automated and easy-to-use option for clinical practice.

Términos MeSH

Aged Aged, 80 and over Female Humans Image Processing, Computer-Assisted Macula Lutea Male Middle Aged Retinal Perforations Retinal Pigment Epithelium Retrospective Studies Tomography, Optical Coherence